The MIL-STD-461 standard requires absorption starting from 80MHz. With the HC-50TR absorber, it is possible to meet this standard using only the truncated pyramidal absorber, without the need for ferrite tiles. This provides several benefits, including a reduction in the cost and time required for construction, as fewer materials are needed.
Additionally, the relatively low height of the HC-50TR absorber results in a more efficient use of space inside the chamber, providing more room for testing equipment and personnel.
Overall, the HC-50TR absorber provides a cost-effective solution for meeting the MIL-STD-461 standard in an anechoic chamber.
Model | 80MHz | 120MHz | 250MHz | 500MHz | 1GHz | 5GHz | 10GHz | 18GHz |
HC-50TR | -7 dB | -20 dB | -20 dB | -23 dB | -23 dB | -30 dB | -25 dB | -27 dB |
Base Size(cm) | 60 x 60 |
Max Service Temperature | 100°C |
Power Handling Capacity | 1.5 kW/m² or 752 V/m |
Fire Retardancy | UL94 HBF / DIN 4102 Class B2 |
Cleanroom Equipment Suitability | ISO 14644 Class 3 |